This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gall, D.
Right arrow Articles by Smith, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gall, D.
Right arrow Articles by Smith, P.

 Previous Article  |  Next Article 

Clinical and Vaccine Immunology, April 2006, p. 501-506, Vol. 13, No. 4
1071-412X/06/$08.00+0     doi:10.1128/CVI.13.4.501-506.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.

Rapid, Field-Adapted Indirect Enzyme-Linked Immunosorbent Assay for Detection of Antibodies in Bovine Whole Blood and Serum to Brucella abortus

D. Gall,* K. Nielsen, W. Yu, and P. Smith

Canadian Food Inspection Agency, Ottawa Laboratory Fallowfield, Ottawa, Ontario, Canada K2H 8P9

Received 21 November 2005/ Returned for modification 21 December 2005/ Accepted 13 January 2006

A simple, rapid, field-adapted indirect enzyme-linked immunoassay (FldELISA) for the detection of antibodies to Brucella abortus in whole blood and serum has been developed. This assay detects antibodies to B. abortus in approximately 15 min or less. Over a 3-month period, this assay has consistently identified immunized and nonimmunized animals, while the percent coefficient of variation for each immunized animal has been less than 20%. As with any indirect enzyme-linked immunoassay, quality control can be established and maintained. Using defined positive and negative sera, the sensitivity and specificity of the FldELISA was 100% and 94.2%, respectively. As a model, this test can be readily extended to other disease applications that use lipopolysaccharide or other stable antigens for the detection of antibodies, such as those to Salmonella spp., Escherichia coli, or Yersinia spp.


* Corresponding author. Mailing address: Canadian Food Inspection Agency, Ottawa Laboratory Fallowfield, 3851 Fallowfield Rd., Ottawa, Ontario, Canada K2H 8P9. Phone: (613) 228-6698. Fax: (613) 228-6667. E-mail: gall{at}inspection.gc.ca.


Clinical and Vaccine Immunology, April 2006, p. 501-506, Vol. 13, No. 4
1071-412X/06/$08.00+0     doi:10.1128/CVI.13.4.501-506.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.