This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Prince, H. E.
Right arrow Articles by Matud, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Prince, H. E.
Right arrow Articles by Matud, J.

 Previous Article  |  Next Article 

Clinical and Vaccine Immunology, February 2006, p. 266-270, Vol. 13, No. 2
1071-412X/06/$08.00+0     doi:10.1128/CVI.13.2.266-270.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.

Evaluation of a Tetraplex Microsphere Assay for Bordetella pertussis Antibodies

Harry E. Prince,* Mary Lapé-Nixon, and Jose Matud

Focus Diagnostics, Cypress, California 90630

Received 17 October 2005/ Returned for modification 1 December 2005/ Accepted 5 December 2005

To increase testing efficiency, a microsphere-based multianalyte immune detection (MAID) system was developed to measure serum immunoglobulin G (IgG) and IgA recognizing two Bordetella pertussis antigens, pertussis toxin (PT) and filamentous hemagglutinin antigen (FHA). The assay was performed as two separate duplexes. One duplex measured IgG to PT and FHA, and the other measured IgA to PT and FHA. The two duplexes were then combined and analyzed as a tetraplex. The MAID system and an in-house enzyme-linked immunosorbent assay (ELISA) system were used to evaluate 100 sera from blood donors and 220 consecutive sera submitted for B. pertussis antibody testing. For both the MAID and ELISA systems, antibody levels were defined as increased if greater than the blood donor group 95th percentile value. The qualitative concordance rates between MAID and ELISA results for the 220 consecutively submitted sera were as follows: PT IgG, 99%; PT IgA, 94%; FHA IgG, 93%; FHA IgA, 94%. The overall concordance rate was 95% (836 of 880 result sets). For 29 of 44 (66%) discordant result sets, the discordant MAID result was supported by the MAID and ELISA results for other B. pertussis antibodies. The MAID and in-house ELISA systems were also used to evaluate 20 sera previously tested for pertussis antibodies at a pertussis vaccine research laboratory; MAID results for all four analytes did not significantly differ from results obtained by the research laboratory. These findings show that antibodies to B. pertussis antigens can be measured easily and accurately using a tetraplex microsphere system.


* Corresponding author. Mailing address: Focus Diagnostics, 5785 Corporate Avenue, Cypress, CA 90630. Phone: (714) 503-2047. Fax: (714) 484-1296. E-mail: hprince{at}focusdx.com.


Clinical and Vaccine Immunology, February 2006, p. 266-270, Vol. 13, No. 2
1071-412X/06/$08.00+0     doi:10.1128/CVI.13.2.266-270.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Raedler, M. D., Heyne, S., Wagner, E., Shalkowski, S. K., Secore, S., Anderson, A. S., Cook, J., Cope, L., McNeely, T., Retzlaff, M., Shanter, J., Rubinstein, L. J., Green, T., Kartsonis, N., Esser, M. T. (2009). Serologic Assay To Quantify Human Immunoglobulin G Antibodies to the Staphylococcus aureus Iron Surface Determinant B Antigen. CVI 16: 739-748 [Abstract] [Full Text]  
  • de Voer, R. M., Schepp, R. M., Versteegh, F. G. A., van der Klis, F. R. M., Berbers, G. A. M. (2009). Simultaneous Detection of Haemophilus influenzae Type b Polysaccharide-Specific Antibodies and Neisseria meningitidis Serogroup A, C, Y, and W-135 Polysaccharide-Specific Antibodies in a Fluorescent-Bead-Based Multiplex Immunoassay. CVI 16: 433-436 [Abstract] [Full Text]  
  • de Voer, R. M., van der Klis, F. R. M., Engels, C. W. A. M., Rijkers, G. T., Sanders, E. A., Berbers, G. A. M. (2008). Development of a Fluorescent-Bead-Based Multiplex Immunoassay To Determine Immunoglobulin G Subclass Responses to Neisseria meningitidis Serogroup A and C Polysaccharides. CVI 15: 1188-1193 [Abstract] [Full Text]  
  • Reder, S., Riffelmann, M., Becker, C., Wirsing von Konig, C. H. (2008). Measuring Immunoglobulin G Antibodies to Tetanus Toxin, Diphtheria Toxin, and Pertussis Toxin with Single-Antigen Enzyme-Linked Immunosorbent Assays and a Bead-Based Multiplex Assay. CVI 15: 744-749 [Abstract] [Full Text]