CVI
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Johnson, A. J.
Right arrow Articles by Biggerstaff, B. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johnson, A. J.
Right arrow Articles by Biggerstaff, B. J.

 Previous Article  |  Next Article 

Clinical and Diagnostic Laboratory Immunology, May 2005, p. 566-574, Vol. 12, No. 5
1071-412X/05/$08.00+0     doi:10.1128/CDLI.12.5.566-574.2005

Duplex Microsphere-Based Immunoassay for Detection of Anti-West Nile Virus and Anti-St. Louis Encephalitis Virus Immunoglobulin M Antibodies

Alison J. Johnson,* Amanda J. Noga, Olga Kosoy, Robert S. Lanciotti, Alicia A. Johnson, and Brad J. Biggerstaff

Division of Vector-Borne Infectious Diseases, National Center for Infectious Diseases, Centers for Disease Control and Prevention, Public Health Service, U.S. Department of Health and Human Services, Fort Collins, Colorado 80522

Received 9 November 2004/ Returned for modification 5 January 2005/ Accepted 28 February 2005

West Nile (WN) virus was introduced into the United States in 1999, when the first human cases of WN fever and encephalitis appeared in New York City. From there, the virus has spread throughout North America, in some areas cocirculating with the related flavivirus St. Louis encephalitis (SLE) virus. Public health laboratories currently use an immunoglobulin M (IgM) antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) as a primary test for human serodiagnosis, followed by a confirmatory plaque-reduction neutralization test (PRNT). The MAC-ELISAs take 2 days to perform; therefore there is a need for a more rapid test. This report describes a duplex microsphere-based immunoassay (MIA) that shortens the test processing time to about 4.5 h. The assay employs two sets of microspheres coupled to a single flavivirus group-reactive antibody, which are used to capture the WN and SLE viral antigens independently. Immunoglobulin G-depleted serum is concurrently assayed for IgM antibodies to each of the viral antigens. The results are standardized and classified by using quadratic discriminant analysis so that a single result, anti-WN IgM-positive, anti-SLE IgM-positive, negative, or nonspecific, can be determined. The duplex MIA results compared favorably to those of the plaque-reduction neutralization test and MAC-ELISA. The assay proved to be reproducible, produced accurate classifications as to the infecting virus, and was specific.


* Corresponding author. Mailing address: Centers for Disease Control/DVBID, P. O. Box 2087, Fort Collins, CO 80522. Phone: (970) 221-6469. Fax: (970) 221-6476. E-mail: ajj1{at}cdc.gov.


Clinical and Diagnostic Laboratory Immunology, May 2005, p. 566-574, Vol. 12, No. 5
1071-412X/05/$08.00+0     doi:10.1128/CDLI.12.5.566-574.2005