Previous Article | Next Article 
Clinical and Diagnostic Laboratory Immunology, November 2002, p. 1376-1378, Vol. 9, No. 6
1071-412X/02/$04.00+0 DOI: 10.1128/CDLI.9.6.1376-1378.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
Defibrination of Blood Plasma for Use in Serological Tests for Syphilis
Arnold R. Castro,* Susan E. Kikkert, Martha B. Fears, and Victoria Pope
Syphilis and Chlamydia Branch, Division of AIDS, STD, and TB Laboratory Research, National Center for Infectious Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia 30333
Received 30 April 2002/
Returned for modification 22 July 2002/
Accepted 22 August 2002

ABSTRACT
Syphilitic plasma can be salvaged from discarded blood donations
and converted to serum by defibrination. Sixty-nine units of
plasma were treated with a stock solution of 100 U of thrombin
per ml in 1 M calcium chloride and then with a 10% (wt/vol)
solution of kaolin. Fibrinogen concentrations detected in initial
plasma samples ranged from 94 to 4,970 mg/liter (mean, 2,532
mg/liter) for samples that were reactive by the rapid plasma
reagin circle card test (RPR) and from 314 to 2,742 mg/liter
(mean 1,528 mg/liter) for samples that were not reactive by
the RPR. The treated samples showed no measurable fibrinogen
remaining after the defibrination process. In the nontreponemal
RPR for syphilis, 86% of the treated plasma samples retained
the same endpoint titer as that of the initial plasma sample.
When the
Treponema pallidum passive-particle-agglutination test
was used, 98% retained the same reactivity. In the Captia Syphilis-G
enzyme immunoassay, 89% of the treated samples demonstrated
no change in reactivity index, and in the fluorescent treponemal
antibody absorption test, 96% showed no reduction in fluorescence.
Human sera containing antibodies to syphilis are used at the
Centers for Disease Control and Prevention for the preparation
of reference controls or as samples for proficiency testing.
Finding reactive sera is becoming more difficult due to the
general decline of syphilis cases in the United States. The
decreasing availability of these sera can be alleviated by salvaging
plasma and converting it to serum.

TEXT
In the American Public Health Association publication
A Manual of Tests for Syphilis (
3), the Centers for Disease Control and
Prevention recommends that serum be used in the Venereal Disease
Research Laboratory (VDRL) test. Serum should be heated at 56°C
for 30 min prior to testing to inactivate complement (
2), since
the presence of complement in freshly drawn serum makes it less
reactive. The heating of plasma at the same temperature and
for the same period of time enhances fibrin formation (
7), rendering
plasma unsuitable for this test. At the Centers for Disease
Control and Prevention, human sera that are seropositive for
syphilis are used in the preparation of serology reference controls
or as samples for proficiency testing. However, it is becoming
more difficult to find reactive sera because of the general
decline in the number of syphilis cases in this country (
4).
About 12.6 million units of whole blood are donated in the United
States each year. After the blood is drawn, it is tested for
ABO group and Rh type. Screening tests are also performed for
evidence of donor infection with hepatitis viruses B and C,
human immunodeficiency virus types 1 and 2, human T-lymphotropic
virus types I and II, and syphilis (
6). Whole blood for transfusion
is collected into a bag that contains an anticoagulant-preservative
solution designed to prevent clotting and to maintain cell viability
during storage. Commonly used anticoagulants are citrate-phosphate-dextrose,
citrate-phosphate-dextrose-dextrose, and citrate-phosphate-dextrose-adenine.
Citrate prevents activation of the clotting cascade by chelating
calcium, thus inhibiting the several calcium-dependent steps
in coagulation. Blood stored at 1 to 6°C for 21 days retains
15 to 30% of heat-labile coagulation factors V and VIII and
most of the stable factors II, VII, IX, and X (
6). Plasma derived
from blood donations found to be reactive for infectious diseases
is discharged according to the Food and Drug Administration's
Good Manufacturing Practices regulations. However, units of
plasma that are reactive for syphilis but nonreactive for other
diseases can potentially be used for manufacturing syphilis
reference reagents or proficiency test samples. Plasma can be
converted to serum by the method of defibrination. Coagulation
factors present in plasma can be activated to form fibrin, with
the addition of calcium chloride and thrombin (
1). Thrombin
cleaves fibrinogen to form fibrin monomers, which polymerize,
creating a stable clot. Fibrinogen is a symmetrical dimer with
three pairs of polypeptide chains (a, b, and g) linked by disulfide
bonds. Soluble fibrinogen becomes fibrin when thrombin cleaves
arginine-glycine bonds at the amino-terminal ends of the a and
b chains, removing negatively charged fibropeptides A and B.
The remaining fibrin monomers are linked by hydrogen bonds to
form insoluble polymers (
5). The purpose of this study was to
demonstrate that syphilitic plasma derived from whole-blood
donations can be salvaged and then converted to serum for the
purpose of making reference controls and proficiency test samples.
Thrombin stock solution.
A working stock solution of thrombin (Sigma, St. Louis, Mo.) at 100 U/ml in 1 M calcium chloride (Fisher Scientific, Suwanee, Ga.) was prepared, dispensed in 5-ml aliquots, and stored at -20°C until used.
Plasma sample treatment.
Sixty-nine units of plasma from different donors were obtained from the New York Blood Center (New York, N.Y.), Millennium Biotech, Inc. (Ft. Lauderdale, Fla.), and New York Biologicals (Southampton, N.Y.). These units were prescreened and found to be reactive or nonreactive in the serologic tests for syphilis. Ten milliliters of each plasma sample was placed into a 15-ml round-bottom centrifuge tube (Nalgene Nunc International, Rochester, N.Y.), and tubes were incubated in a water bath at 37°C for 30 min. One hundred microliters of thrombin stock solution was added to each sample; samples were incubated for 10 additional minutes and allowed to clot at room temperature for 1 h (1). After clotting, the samples were frozen at -20°C for 2 to 4 h. The samples were then thawed at room temperature, and 1 g of kaolin, which had been washed with distilled water and then dried, was added to each sample; afterward, the suspension was mixed continuously for 4 h with the aid of magnetic bars. The samples were then incubated at 2 to 8°C overnight, with constant gentle agitation at approximately 27 rpm on a tabletop rocker platform. The purpose of the kaolin is to serve as a clarifying medium. The samples were centrifuged at 1,935 x g for 45 min, and the supernate was decanted into another set of centrifuge tubes. The treated plasma was then filtered through 0.45- and 0.22-µm-pore-size filter membranes (Gelman Sciences, Ann Arbor, Mich.).
Sample testing.
Each of the 69 treated plasma samples and its corresponding untreated sample were tested for fibrinogen content by the radial immunodiffusion test (The Binding Site, Birmingham, United Kingdom), the rapid plasma reagin circle card test (RPR), the fluorescent treponemal antibody absorption double-staining test (FTA-ABS DS), the Treponema pallidum passive-particle-agglutination assay (TP-PA) (Fujirebio America, Fairfield, N.J.) (3), and the Captia Syphilis-G immunoassay (EIA) (Trinity Biotech, Bray, Ireland). Treated plasma samples were tested by the VDRL test.
The effectiveness of plasma conversion was measured by comparing the reductions in fibrinogen concentrations in the treated plasma samples to those in the untreated samples. In the untreated samples, fibrinogen concentrations ranged from 94 to 4,970 mg/liter (mean, 2,532 mg/liter) for the RPR-reactive samples and from 314 to 2,742 mg/liter (mean, 1,528 mg/liter) for the RPR-nonreactive samples. The treated samples showed no measurable amount of fibrinogen remaining after the defibrination process. There was no significant loss of reactivity when treated plasma samples were compared with the plasma baseline control samples by either the nontreponemal RPR or the treponemal tests. Of the 48 plasma samples that were reactive by RPR, 41 (85%) retained the same quantitative endpoint titer after treatment while 7 (15%) showed a reduction of one doubling dilution (Table 1). In the TP-PA analysis, 55 of 56 treated samples (98%) retained the same reactivity after treatment and only 1 sample (1.7%) showed a reduction in reactivity from 1+ to negative. Of 56 plasma samples found to be reactive by the EIA, 50 (89%) demonstrated no change in reactivity while 6 (11%) showed a reduction in the antibody index that reflected a change from reactivity to nonreactivity. Among the 54 samples that were reactive by the FTA-ABS DS, 52 (96%) showed no reduction in fluorescence, while 2 (4%) showed a reduction in fluorescence from 1+ to negative (Table 2). Treated plasma samples were also heat inactivated at 56°C for 30 min and subjected to the VDRL test. Of the 69 samples, 46 were reactive and 23 were nonreactive. There was no evidence of false-positive samples resulting from the heat treatment.
View this table:
[in this window]
[in a new window]
|
TABLE 1. Effect of treatment on 48 reactive and 21 nonreactive plasma samples in the nontreponemal RPR for syphilis
|
Concluding remarks.
In this study, we have demonstrated that plasma can be successfully
converted to serum by the addition of 1 ml of thrombin (100
U/ml) in 1 M calcium chloride to 100 ml of plasma, followed
by a 10% (wt/vol) kaolin treatment. The converted plasma thus
obtained is free of fibrin formation even after prolonged storage
at -20 or 2 to 8°C. Converted plasma specimens could be
used in the preparation of proficiency testing samples and as
syphilis serology reference controls. Whole blood collected
with anticoagulant has an approximate dilution ratio of 2.7
ml of plasma to 1 ml of anticoagulant; this dilution ratio,
in addition to the defibrination procedure, is responsible for
some loss in the reactivity of the converted plasma. The loss
of reactivity is meaningful only if the antibody content of
the sample is reduced to a point which affects the desired antibody
titer. With the 69 treated plasma samples, no reduction in antibody
titer was observed in 85% of samples in the nontreponemal RPR
and no change in reactivity was observed for 98% of the samples
in the TP-PA, 89% of those in the EIA, and 96% of those in the
FTA-ABS DS. None of the nonreactive treated plasma samples became
reactive as a result of the defibrination treatment.
Use of plasma is not recommended in the slide VDRL test for syphilis because heat inactivation at 56°C for 30 min enhances fibrin formation and fibrin strands entrap the liposomes present in the VDRL antigen emulsion. Because the slide VDRL test requires that the sample with the added emulsion be rotated at 180 rpm for 4 min, even minute amounts of fibrin aggregate, yielding false-positive results for nonreactive samples. In these studies, the thrombin, calcium chloride, and kaolin treatment removed fibrin from the system to such a degree that no false-positive reactions were obtained.
The syphilis elimination effort has resulted in a general decline in the number of syphilis cases in the United States, from 134,255 in 1990 to 31,575 in 2000. It has therefore become more difficult to obtain moderate- to high-titer sera from persons with syphilis for the purpose of manufacturing reference controls and proficiency test samples used for quality assurance in syphilis testing. The decreasing availability of these sera can be alleviated by salvaging plasma from blood donations that would normally be discarded because of syphilis seroreactivity and then converting the plasma to serum to be used in the treponemal and nontreponemal tests for syphilis.

FOOTNOTES
* Corresponding author. Mailing address: Division of AIDS, STD, and TB Laboratory Research, Centers for Disease Control and Prevention, 1600 Clifton Rd, Mail Stop D-13, Atlanta, GA 30333. Phone: (404) 639-2874. Fax: (404) 639-3976. E-mail:
acastro{at}cdc.gov.


REFERENCES
1 - Johnstone, A., and R. Thorpe (ed.). 1987. Immunochemistry in practice, 2nd ed., p. 34. Blackwell Scientific Publications, Oxford, United Kingdom.
2 - Lantz, M. A., and V. H. Falcone. 1968. The necessity for heating sera for the VDRL slide test. Am. J. Med. Technol. 34:551-556.[Medline]
3 - Larsen, S. A., V. Pope, R. E. Johnson, and E. J. Kennedy, Jr. (ed.). 1998. A manual of tests for syphilis, 9th ed., p. 223-245, 363-378. American Public Health Association, Washington, D.C.
4 - St. Louis, M. E., and J. N. Wasserheit. 1998. Elimination of syphilis in the United States. Science 281:353-354.[Free Full Text]
5 - University of Alberta. 2000. Clotting cascade & current concepts of blood coagulation. [Online.] http://brie.medlabscience.med.ualberta.ca/mlsci/235/clotcascade.html.
6 - Vengelen-Tyler, V. (ed.). 1999. Technical manual, 13th ed., p. 149-159. American Association of Blood Banks, Bethesda, Md.
7 - Wotkuh-Wocadkuu, B. A. 1970. Defibrination of blood plasma for obtaining hemagglutinating sera. Probl. Gematol. Pereliv. Krovi 15:48-49.[Medline]
Clinical and Diagnostic Laboratory Immunology, November 2002, p. 1376-1378, Vol. 9, No. 6
1071-412X/02/$04.00+0 DOI: 10.1128/CDLI.9.6.1376-1378.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.