U.S. Military HIV Research Program, Rockville, Maryland,1 JPT Peptide Technologies, Berlin, Germany,2 National Institute for Communicable Diseases, Sandringham, Johannesburg, South Africa,3 Armed Forces Research Institute of Medical Sciences, Bangkok, Thailand,4 Mbeya Medical Research Programme, Mbeya, Tanzania,5 Department of Infectious Diseases and Tropical Medicine, University of Munich, Munich, Germany6
Received 11 July 2007/ Returned for modification 9 October 2007/ Accepted 21 November 2007
|
|
|---|
1% by weight of the HCMV peptide. These observations have critical implications for quality assurance (QA) and quality control (QC) of peptides used in clinical trials where cellular immune-based assays are important end-point determinants. We propose a simple schema of biological QA/QC protocols to augment the standard biochemical QA/QC analyses as a means to circumvent this and other problems that can affect cellular immune-based assay outcome and interpretation. |
|
|---|
In this report, we describe two case studies of problematic contamination of individual peptides from human immunodeficiency virus (HIV-1)-based peptide sets with a commonly used peptide from human cytomegalovirus (HCMV). In the first case, the contaminated peptide was proven to have come directly from the manufacturer, while in the second case, three different peptides from a single HIV-1-based peptide set were shown to have been most likely contaminated in the hands of the manufacturer. While the level of contaminating peptide was shown to be relatively low (
1% or less of the total peptide weight), the extraordinary sensitivity of T cells for their cognate antigen resulted in detection of peptide-specific responses in both ELISPOT and CFC assays. Such contamination, if not detected, could lead to false-positive interpretations of important research and clinical trial data. Both research and clinical assessment laboratories should be aware of the possibility of peptide cross-contamination and other potential impurities and perform appropriate biological as well as biochemical QA/QC on all peptides. Peptide manufacturers and suppliers should also be made aware of this problem and implement the appropriate changes to their current QA/QC procedures to further ensure against this problem.
|
|
|---|
Synthetic peptides. The sequence, origin, and location of single peptides used in this study are detailed in Table 1. Briefly, the Gag 114 peptide was derived from the HIV-1 Gag p6 protein (positions 453 to 467) of CRF01_AE isolate 90CF402 and was originally part of an overlapping-peptide set (15 amino acids in length with an 11-amino-acid overlap) designed for screening for subtype A Gag-specific T-cell responses from eastern African HIV-1-infected cohorts (6, 13). This peptide was obtained from "manufacturer A" in 20 individual vials of 1 mg each; each vial was hermetically sealed. The Gag (CM240 isolate), Pol (CM240 isolate), and Env (CM235 isolate) overlapping peptide sets (15 amino acids in length with an 11-amino-acid overlap) were obtained from "manufacturer B." The HCMV pp65 NV9, Gag (90CF402) 114, Env (CM235) 97, Env (CM235) 137, and Pol (CM240) 31 peptides were resynthesized in-house (Henry M. Jackson Foundation) with free amino termini using 9-fluorenylmethoxy carbonyl (Fmoc) chemistry and standard solid-phase techniques (Excel automated synthesizer; Waters, Milford, MA). The CEF peptide set was also synthesized in-house (Henry M. Jackson Foundation). All peptides were >80% pure as determined by high-performance liquid chromatography (HPLC) and verified for correct sequence by mass spectroscopy (MS). In some cases, amino acid analysis and N-terminal sequencing were also performed. The HPLC-MS analysis was performed by JPT Peptide Technologies (Berlin, Germany) using an LC-MSD Trap LC device 1100 series (Agilent, Waldbronn, Germany).
|
View this table: [in a new window] |
TABLE 1. Source proteins and sequences of peptides used in the study
|
) was employed to measure the frequency of peptide-specific CD8 T cells in cryopreserved PBMC from HIV-1-infected and uninfected subjects directly. The assay was performed as described in detail elsewhere previously (5, 6). Briefly, cryopreserved PBMC were thawed, washed, and rested overnight in CM for 14 to 16 h. After overnight resting, the PBMC were enumerated prior to addition to prewetted, primary-antibody-coated (1-D1K; Mabtech AB, Sweden) ELISPOT assay plates (Multiscreen-IP plates, MAIP-type plates; Millipore, MA). Approximately 1 x 105 to 2 x 105 viable PBMC were plated per well for all assays. Plates were incubated for 18 to 20 h prior to washing and the addition of the secondary biotinylated mouse anti-human IFN-
monoclonal antibody (7B6-1-biotin; Mabtech AB, Sweden). Assay spot development was performed using the avidin horseradish peroxidase complex system (Vectastain ABC kit; Vector Laboratories, CA). Peptides were used at a final concentration of 1 to 2 µg/ml and were prefiltered for some assays as noted. As a positive control for functional integrity of the PBMC, staphylococcal entertoxin B (SEB) was added to wells at a final concentration of 5 µg/ml, and cells were incubated with CM only as a negative control. The plates were evaluated with an automated ELISPOT reader system and KS 4.3 software (Carl Zeiss, Thornwood, NY). Plates were read and spots were counted by an independent scientist (Henry M. Jackson Foundation, Rockville, MD). Positive IFN-
spot-forming cells (SFC) representing single cells were counted and expressed as SFC per 1 million input PBMC. Assays were considered to be valid if responses of greater than 500 SFC per 1 million input PBMC were detected with SEB. Cytotoxic T-lymphocyte effector cell generation. Effector cells were prepared by in vitro stimulation (IVS) of thawed, cryopreserved PBMC. Peptide-pulsed (10 µM overnight), irradiated (10,000-rad), autologous BLCL (Epstein-Barr virus-transformed B-cell line) or allogeneic (HLA-A0201-positive) BLCL (2 x 106 cells) were washed three times with CM and then cocultured with 10 x 106 to 20 x 106 PBMC in 10 ml CM supplemented with 5 ng/ml recombinant human interleukin-7 (rhIL-7) (R&D Systems, Minneapolis, MN) for 4 days. A total of 5 ng/ml rhIL-2 (R&D Systems, Minneapolis, MN) was then added to the cocultures, and the cultures were maintained and split with fresh CM and rhIL-2 for up to 24 days. Effector cell lines were then maintained by restimulation every 7 to 14 days with irradiated, peptide-pulsed BLCL (HLA-A0201-positive) and 5 ng/ml rhIL-2 in CM.
CFC assay.
Cryopreserved PBMC were thawed rapidly, washed twice with CM, and either used immediately or incubated at 2 x106 to 5 x106 cells/ml in CM for 14 to 16 h. PBMC rested overnight were recounted prior to assay. Effector cells (prepared above) or PBMC were added at 0.5 x 106 to 1.0 x 106 cells per well into 96-well polypropylene tissue culture trays (catalog no. 3790; Costar) and stimulated either directly with peptide or with autologous or allogeneic peptide-pulsed BLCL. BLCL were pulsed overnight with the relevant peptide (10 µg/ml), washed five times after overnight incubation, and distributed at 1 x105 cells per well (ratio of PBMC or effector cells to BLCL of 5:1 to 10:1). As a positive control for functional integrity of the cryopreserved cells, SEB was added to a single well at a final concentration of 5 µg/ml. The assay mixtures were incubated for 6 h at 37°C (5% CO2) in the presence of the protein transport inhibitor brefeldin A (10 µg/ml; Sigma, St. Louis, MO) and were then interrupted by transfer to a reduced temperature (either 4°C or 18°C). Cells were stained for surface markers and intracellular IFN-
expression (CFC assay) on the following day. Cocultured PBMC or effector cells (prepared as described above) were washed once with flow buffer (DPBS-0.1% bovine serum albumin-0.1% sodium azide) and incubated in 96-well tissue culture trays for 10 min in 200 µl flow buffer at room temperature (the same volume, temperature, and base buffer were used for all subsequent washings and incubations) containing 1 mM EDTA. Cells were washed once, fixed in 2% formaldehyde for 30 min, and washed again. Fixed cells were permeabilized with 0.5% saponin (Sigma, St. Louis, MO) for 30 min, washed, and resuspended in 0.5% saponin containing the following monoclonal antibodies: fluorescein isothiocyanate (FITC)-conjugated anti-IFN-
(clone 25723.11), phycoerythrin (PE)-conjugated anti-CD69 (clone L78); PerCP-Cy5.5-conjugated anti-CD8 (clone SK1), and allophycocyanin (APC)-conjugated anti-CD3 (clone SK7) (BD Biosciences, San Jose, CA). After 30 min of incubation, cells were washed three times with flow buffer and finally resuspended in 200 µl flow buffer. Stained cells were stored at 4°C and analyzed by flow cytometry within 24 h.
Flow cytometry and analysis. Phenotypic analysis of PBMC and cytotoxic T-lymphocyte effector cells for the expression of T-cell receptors specific for the HCMV-NV9 epitope was performed using the iTAg major histocompatibility complex class I human tetramer PE system (Beckman Coulter Immunomics, San Diego, CA). Cells were stained for 30 min at room temperature in flow buffer containing tetramer and either FITC- or APC-conjugated anti-CD8 (clone SK1) and then fixed with 2% formaldehyde prior to flow cytometry acquisition and analysis. Data acquisition was performed using a FACScalibur flow cytometer (Becton Dickinson, San Jose, CA). Initial gating was performed using a total lymphocyte gate based on forward- and side-scatter characteristics and the acquisition of 50,000 to 200,000 cells within this gate. Color compensation was performed using similarly prepared cells from an HIV-1-seronegative donor and staining singly labeled cells with anti-CD3 labeled with FITC, PE, PerCP-Cy5, and APC fluorochromes (BD Biosciences). Data sets were analyzed using FlowJo software (version 4; TreeStar, Cupertino, CA).
Statistical analysis. In the ELISPOT assays, the cutoff for positivity was a count of >55 SFC per 1 million input PBMC and more than four times the background (mean of the negative-control wells) (12). Nonparametric tests were used for comparing the nonpaired peptide responses between the HIV-1-seronegative and -seropositive groups (Mann-Whitney rank test) and for comparing the paired peptide responses within the groups (Wilcoxon signed-rank test).
|
|
|---|
-producing CD8 cells from PBMC of HLA-A0201 individuals independent of their HIV serostatuses.
An immunodominant response directed against HIV-1 Gag peptide 114 (provided by manufacturer A) was observed while screening for HIV-specific CD8+ T-cell responses in a cohort of HIV-1 subtype A-infected individuals and in a cohort of HIV-1-exposed yet -uninfected subjects. In addition, a similar frequency of IFN-
SFCs were detected in response to either Gag 114 or a pool of positive-control peptides (CEF peptide pool) (5), representing optimal broadly recognized CD8 epitopes, in four HEPS subjects. High-resolution HLA typing revealed that all subjects responding to Gag 114 possessed the HLA-A0201 allele. Since preliminary data had shown that the majority of the response against the CEF peptide pool in HLA-A0201-positive subjects was directed toward the HCMV-NV9 peptide, we tested the hypothesis that there was an association between the responses to the HCMV-NV9 peptide and the Gag 114 peptide. Figure 1A shows that both the HCMV-NV9 and Gag 114 peptides induced positive IFN-
ELISPOT responses in PBMC from 7/8 HIV-1-seropositive, HLA-A0201-positive subjects; 10/12 HIV-1-seronegative, HLA-A0201-positive subjects; and 0/9 HIV-1-seronegative, HLA-A0201-negative subjects. The ability to respond to either peptide was independent of HIV-1 serostatus and was dependent upon the possession of the HLA-A0201 allele, since only HLA-A0201-positive subjects respond to both peptides, and HLA-A0201-negative subjects respond to neither peptide. Importantly, four of the HIV-1-seronegative, HLA-A0201-positive subjects were exposed to HIV-1 but were uninfected, and each subject demonstrated strong and equivalent HCMV-NV9 and Gag 114 responses (Fig. 1A, open circles). There was no significant difference in the magnitudes of the responses to HCMV-NV9 or Gag 114 between HIV-1-seropositive and -seronegative subjects (Mann-Whitney rank test) (Fig. 1A). There was, however, a significant difference in HCMV-NV9 and Gag 114 responses within both seropositive and seronegative subject groups (Wilcoxon signed-rank test) (Fig. 1A). A strong positive correlation (r2 = 0.90) between the magnitudes of responses to each peptide in all responders, irrespective of HIV-1 serostatus, was demonstrated (Fig. 1B). The slope of the linear regression equation for HCMV-NV9 versus Gag 114 responses shows that the magnitude of the response to Gag 114 was approximately 80% of the response to HCMV-NV9. Importantly, three HLA-A0201-positive subjects (one HIV-1-seropositive subject and two HIV-1-seronegative subjects) who did not respond to the HCMV-NV9 peptide also did not respond to the Gag 114 peptide. These data strongly imply that either a large proportion of the T cells responding to the HCMV-NV9 peptide were cross-reactive with the HIV-1 Gag 114 peptide or the Gag 114 peptide was contaminated with the HCMV-NV9 peptide.
![]() View larger version (36K): [in a new window] |
FIG. 1. Cumulative ELISPOT responses to the HCMV-NV9 and Gag 114 peptides from 8 HIV-1-seropositive, HLA-A0201-positive subjects; 12 HIV-1-seronegative, HLA-A0201-positive subjects, and 9 HIV-1-seronegative, HLA-A0201-negative subjects. (A) Responses are plotted on a linear scale of IFN- SFC/106 PBMC, with subjects stratified according to HIV-1 serostatus and possession of the HLA-A0201 allele. P values for comparing the HCMV-NV9 and Gag 114 responses within each group (Wilcoxon signed-rank test) and for comparing HCMV-NV9 or Gag 114 responses between groups (Mann-Whitney rank test) are shown. HIV-1-exposed yet -uninfected subjects within the HIV-1-seronegative groups are indicated with open circles. Neg Con, negative control. (B) Scatter plot of all HCMV-NV9 and Gag 114 responder subjects (n = 17) showing the positive correlation of the HCMV-NV9 response with the Gag 14 response. HIV-1-seropositive (filled circles) (n = 7) and -seronegative (open circles) (n = 10) subjects are indicated. (C) Cryopreserved PBMC from an HIV-1-seronegative subject and PBMC subjected to a 14-day IVS with either HCMV-NV9 or Gag 114 peptide were tested for their abilities to respond to sham-pulsed, HCMV-NV9-pulsed, or Gag 114-pulsed autologous BLCL in a CFC assay for IFN- production. After IVS with either peptide, an approximately 10-fold expansion of CD8+ T cells specific for both peptides was observed (middle row, HCMV-NV9; bottom row, Gag 114). The percentage of HCMV-NV9 tetramer-positive cells among the total CD8+ T-cell population in the IVS is indicated above the gate marker in each histogram. All panels were derived from the gate containing the CD3+ CD8+ T-cell population.
|
demonstrated a robust and equivalent frequency of CD3+ CD8+ T cells responding to either HCMV-NV9 or Gag 114 peptide (4.53% and 4.84%, respectively) (Fig. 1C, top row). An HLA-A201-NV9 tetramer bound directly at a frequency of CD8+ T cells (4.47%) similar to that detected by the IFN-
CFC assay. After the IVS with either HCMV-NV9 or Gag 114 peptides, there was a striking increase (
10-fold) in the number of HCMV-NV9- and Gag 114-responsive CD8+ T cells in both culture systems. Confirmation of the cross-stimulatory capacity between HCMV-NV9 and Gag 114 peptides came from the tetramer staining of both 14-day IVS cultures (Fig. 1C, right panels). Virtually identical numbers of HLA-A0201-NV9 tetramer-positive cells were expanded in each culture (61.3% versus 61.4%). An alignment of the two peptides (Table 1) shows that they share very little primary sequence identity. Hence, direct cross-reactivity between the two peptides seemed unlikely, and contamination of Gag 114 with HCMV-NV9 was the most likely reason for these unusual observations.
Confirmation that the manufacturer-provided Gag 114 peptide was contaminated with the HCMV-NV9 peptide.
To test whether the Gag 114 peptide was indeed contaminated with the HCMV-NV9 peptide, the Gag 114 peptide was resynthesized in-house (Henry M. Jackson Foundation) and tested for its ability to stimulate T cells from an HCMV-NV9 responder HIV-1-seronegative subject. A CFC assay for IFN-
was set up to directly compare the original Gag 114, the in-house-synthesized Gag 114, and the HCMV-NV9 peptides. Autologous BLCL were pulsed with serially 10-fold-titrated concentrations of each peptide and then used to stimulate PBMC from responder subject BC238. Figure 2 shows clearly that peptide HCMV-NV9 stimulates CD8 T cells at much lower concentrations than does the original Gag 114 peptide. Half-maximal stimulation for the HCMV-NV9 peptide (
1 nM) was approximately 100-fold greater than that for the original Gag 114 peptide (
100 nM). The in-house-synthesized Gag 114 had no such stimulatory capacity throughout the same concentration range. This result is consistent with a small amount of HCMV-NV9 contaminating the original Gag 114 peptide.
![]() View larger version (14K): [in a new window] |
FIG. 2. Titration of the CD8+ T-cell response to the original Gag 114 peptide, the resynthesized Gag 114 peptide, and the HCMV-NV9 peptide. Autologous BLCL were pulsed with serial 10-fold dilutions of each peptide and then used as antigen-presenting cells in a CFC assay for IFN- up-regulation in cryopreserved PBMC from a known HIV-1-seronegative, HCMV-NV9 responder subject. Results are expressed as the percentages of IFN- -positive cells in the CD3+ CD8+ T-cell population. The dotted line shows the interpolated peptide concentration at which the 50% maximal response to the HCMV-NV9 peptide occurred.
|
![]() View larger version (25K): [in a new window] |
FIG. 3. LC-MS analysis of the suspect contaminated Gag 114 peptide from manufacturer A (A to C) and the in-house-resynthesized Gag 114 peptide (D to F). (A and D) UV traces of HPLC. High peptide purity is evident. The selected ion mode with mass filter adjusted to the calculated theoretical mass of the Gag 114 peptide (1,559.80 [M + H]+) is shown for each peptide (B and E). The desired product is clearly present in both profiles. The selected ion mode with mass filter adjusted to the calculated theoretical mass of the HCMV-HCMV-NV9 peptide (944.18 [M + H]+) is shown (C and F). A signal corresponding the exact theoretical molecular weight (MW) of HCMV-NV9 is present in the outsourced Gag 114 peptide. Note the different scales on the y axes.
|
that was comparable to their response to the CEF control peptide pool. No inhibitory activity was detected in any of the subjects tested (n = 23) (data not shown). Figure 4 shows the responses of four HIV-1-seronegative subjects to the Gag, Env, and Pol peptide pools. Three subjects responded to the Pol pool, two responded to the Env pool, and none responded to the Gag pool. All four subjects responded well to the positive-control CEF peptide pool, and all responses were CD8 mediated. Of note was that all three HIV-1-derived peptide pool-responding subjects possess the HLA-A0201 allele. Testing of all the individual peptides that make up each pool was carried out to determine which peptide(s) was responsible for the spurious CD8 T-cell activation. An IFN-
ELISPOT assay of 326 individual peptides (179 from Env and 147 from Pol) in two subjects (one HLA-A0201 positive and one HLA-A0201 negative) revealed that three peptides could stimulate PBMC from the HLA-A0201-positive subject (Fig. 4C). These peptides, Env 97, Env 137, and Pol 31, were then confirmed to be HLA-A0201 restricted in a CFC assay for IFN-
. As shown in Fig. 5, the response to all three peptides was HLA-A0201 restricted. Filtering of the peptide pools to remove possible insoluble peptide complexes, which have been shown to give false-positive responses in ELISPOT assays (18), did not result in any diminution of the response in an ELISPOT assay for IFN-
(data not shown). Furthermore, the Env and Pol peptide pools were remade without the identified contaminating peptides, and IFN-
ELISPOT responses were screened using 23 subjects. Only one subject exhibited a marginally positive response by our stringent positive-response cutoff criteria (63 SFC/106 PBMC; cutoff, 55 SFC/106 PBMC), a response which we consider to be "noise" in the assay system. Resynthesis of the Env 97, Env 137, and Pol 31 peptides was carried out, and each of the new peptides was retested in an ELISPOT assay for IFN-
using PBMC from the donors for whom responses were detected previously. None of the three resynthesized peptides stimulated a response in our assay system. Taken together, these data provide evidence that three peptides from manufacturer B were capable of stimulating immune responses consistent with classical HLA restriction.
![]() View larger version (33K): [in a new window] |
FIG. 4. Evidence of peptide contamination within two pools of overlapping peptide sets obtained from manufacturer B. Cryopreserved PBMC from four HIV-1-seronegative subjects were tested for their ability to respond to three different HIV-1-derived peptide pools (Gag, Pol, and Env) in a CFC assay for IFN- production. Note that only the subjects possessing the HLA-A0201 allele respond to the Env and Pol peptide sets, and the response is observed within the CD3+ CD8+ T-cell population (A) but not the CD3+ CD4+ T-cell population (B). (C) IFN- ELISPOT response from an HIV-1-seronegative subject to all individual peptides (326 peptides) from the Env (179 peptides) and Pol (147 peptides) peptide sets. Three peptides, Env 97, Env 137, and Pol 31 (indicated with circles), were identified clearly as positive stimulators of IFN- production in the HLA-A0201-positive subject (subject BC238). Pos, positive; Neg, negative.
|
![]() View larger version (33K): [in a new window] |
FIG. 5. The three stimulatory peptides, Env 97, Env 137, and Pol 31, mediate their effect in an HLA-A0201-dependent manner. Cryopreserved PBMC from three HIV-1-seronegative subjects were tested for their abilities to respond to Env 97, Env 137, and Pol 31 peptides alone or pulsed onto autologous and partially HLA-matched BLCL in a CFC assay for IFN- production. The percentage of IFN- -positive cells within the gated CD3+ CD8+ T-cell population is shown. The HLA type of each subject and cocultured BLCL is shown below the bar graphs. The common allele shared by the responding subject and stimulating peptide-pulsed BLCL is shown.
|
|
|
|---|
As described above, during screening of HIV-1-seropositive and -seronegative subjects with an HIV-1 Gag protein-based peptide set (derived from isolate 90CF402), we found that one particular peptide (Gag 114) gave consistently high CD8+ T-cell-mediated IFN-
responses regardless of the HIV-1 serostatus of the subject. The subsequent demonstration that this was the result of a false-positive effect caused by the contamination of the HIV-1 Gag peptide with a commonly recognized peptide from HCMV was both surprising and alarming. Clear evidence that a peptide obtained directly from a supplier contained a significant amount of another peptide (
1% of the total weight) should be disconcerting to all investigators currently studying cellular immune responses using synthetic peptides. The identified contaminating peptide (HCMV pp65495-503) is used extensively as a positive control for ELISPOT and CFC assays in clinical trials and as a reagent for the study of cellular immune responses to chronic viral infection (5, 14, 26, 30). Furthermore, responses detected in subsequent ELISPOT and CFC assays would ostensibly have all the hallmarks of a classical T-cell-mediated response: a high frequency of IFN-
-producing cells, HLA restriction, and immunodominance. Hence, peptide cross-contamination carries with it the likelihood that it would be easily mistaken as a T-cell response against the test peptide and therefore be misinterpreted as a false-positive result. Further cause for concern was raised following routine quality control testing of an additional three HIV-1-derived overlapping peptide sets obtained from a different supplier, two of which demonstrated convincing evidence of contamination of three more individual HIV-1 peptides. While conventional biochemical analysis could not be used to verify the identity of the contaminating peptide(s) involved in this case (all of the peptides were dissolved in DMSO), circumstantial evidence indicated that it was another commonly recognized HLA-A0201-restricted peptide, possibly the same HCMV-derived peptide responsible for the first case of contamination. Such potential contamination has also been described in a recent report, where false-positive responses to a synthetic peptide pool were detected in subjects with a particular HLA type (7). Resynthesis of the suspect individual peptides resulted in the removal of the false-positive response and presumably the contaminant. Therefore, it seems unlikely that the effects that we have observed are spurious events or are specific to our laboratory.
Certainly, the vast majority of peptides obtained from custom peptide suppliers are of the highest quality and are not cross-contaminated; however, the consequence of even a single contaminated peptide making its way into a clinical trial is considerable. This leads to an important question: how did the peptides become contaminated? Since the vast majority of the lyophilized peptide received from the supplier was indeed the intended product, the possibility of simple mislabeling or mix-up of the product vials during or after synthesis can be ruled out. Therefore, contamination at some point during the synthesis, purification, or vialing of the product was the likely source of the contamination. Since contamination may occur simply as a result of improperly cleaned glassware or other apparatuses, this implies that synthetic peptide suppliers need to implement more stringent QA/QC practices for synthetic peptide manufacture.
Both the nature of the contamination—peptides commonly recognized by CD8+ T cells—and the fact that it has been documented in four different peptides obtained from two different manufacturers raise important questions for future QA/QC assessment of peptides slated for future use in cellular immune function assays. While nonspecific cellular immune response-inhibitory and -stimulatory functions of peptide sets can be, and usually are, easily screened for prior to use, potential cross-contamination of peptides with other peptides (often used for positive controls) is not screened for routinely and adds an extra level of complexity to the QA/QC process. It is important that the currently employed methods for QA/QC of synthetic peptides, various combinations of HPLC, mass spectroscopy, amino acid content analysis, and amino acid sequencing, cannot be used routinely to detect potential cross-contaminating peptides. In fact, it is the extraordinary sensitivity of T cells for their cognate antigens that facilitated the detection of the contaminating peptides. T cells can recognize their specific cognate peptides at subnanomolar concentrations, levels at which it is impossible for conventional analytical chemical and biochemical methods to discern a possible contaminant in the presence of overwhelming quantities of another peptide.
The most sobering prospect that emerges from these findings is that we have managed to detect the particular contaminating peptide only because it represents an epitope from HCMV that is recognized frequently in the human populations that we were studying. It is therefore not unreasonable to assume that peptide cross-contamination occurs more frequently and that the general research community has not yet screened for it appropriately. A recent study has shown that Fmoc-modified peptides, a common minor contaminant in synthetic peptides, can directly stimulate human CD4+ T-cell clones (23). As with the cross-contamination that we have described here, the contaminating Fmoc-modified peptides were present at very low levels within the desired product (<0.5%). Therefore, cross-contaminating peptides and peptide synthesis side-reaction adducts could both contribute to spurious false-positive responses in assays for cellular immune responses even when present in sparing quantities.
We recommend that a robust biochemical and biological QA/QC protocol (Table 2) be followed prior to the use of custom synthetic peptides in clinical trial protocols involving measurements of cell-mediated immunity. While important QA procedures such as careful peptide set design (2, 8, 9, 20), biochemical analysis, and selection of appropriate peptide solvent (18) are standard practice for most laboratories, real-world biological assay screening of synthetic peptide sets is not routinely conducted. The selection of an appropriate sample size for the biological screening of the peptides will be dependent upon the HLA diversity in the population studied. Obviously, suppliers and manufacturers must be alerted to the potential problem of peptide cross-contamination that can occur during synthesis and fine-tune their synthesis protocols to account for this problem. Current standard biochemical QA/QC analyses such as HPLC, mass spectrometry, and amino acid sequencing are still recommended, as they ensure that the vast majority of the synthesis product is indeed the correct peptide. Biological QA/QC would complement the biochemical QA/QC procedures (Table 2) and provide an explicit validation of both the peptide and any unavoidable impurities in the assay system to be used for a clinical trial or research protocol. In light of the potential peptide cross-contamination issues that we have described here, researchers should be advised to perform their own regular and robust QA/QC of synthetic peptides used for all research and clinical assay protocols.
|
View this table: [in a new window] |
TABLE 2. Critical parameters and checkpoints in the biochemical and biological QA/QC of synthetic peptides prior to use in assays of cell-mediated immunity
|
Financial support was provided by Department of Defense Collaborative agreement DAMD17-98-2-8007.
The opinions or assertions contained herein are the private views of the authors and are not to be construed as official or as reflecting the views of the Departments of the Army and Defense.
Published ahead of print on 12 December 2007. ![]()
|
|
|---|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||