Previous Article | Next Article ![]()
Clinical and Vaccine Immunology, February 2006, p. 266-270, Vol. 13, No. 2
1071-412X/06/$08.00+0 doi:10.1128/CVI.13.2.266-270.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.
Focus Diagnostics, Cypress, California 90630
Received 17 October 2005/ Returned for modification 1 December 2005/ Accepted 5 December 2005
|
|
|---|
|
|
|---|
The two major antigens utilized for pertussis antibody assays are pertussis toxin (PT) and filamentous hemagglutinin antigen (FHA). Because PT is produced only by B. pertussis (13), an increased level of PT antibodies is highly specific for B. pertussis infection. FHA antibodies are also typically increased following B. pertussis infection but are less specific than PT antibodies; antibodies cross-reactive with B. pertussis FHA may be produced following infection with other Bordetella species, Mycoplasma pneumoniae, Chlamydia pneumoniae, or nonencapsulated Haemophilus influenzae (3, 10). Detection of immunoglobulin G (IgG) to PT and FHA is more sensitive than detection of IgA, since not all exposed individuals mount a detectable IgA response (9, 13, 15).
We currently measure IgG and IgA recognizing PT and FHA using separate in-house enzyme-linked immunosorbent assays (ELISAs). These assays are labor intensive and require substantial amounts of antigens for coating plates. In the studies presented here, we evaluated an in-house multianalyte immune detection (MAID) system for measuring these antibodies. Central to the MAID system is the use of multiple polystyrene bead sets, each containing a distinctive proportion of red and orange fluorescent dyes and thus exhibiting a signature fluorescent pattern (1, 16). A given antigen is covalently linked to a given bead set, and then different bead sets are mixed together with human serum in a single reaction well. After washing and addition of a fluorescent reporter antibody recognizing a specific human immunoglobulin isotype, the bead mixture is analyzed using a modified flow cytometer. Each bead set is identified by its signature fluorescent pattern and is then analyzed for fluorescence characteristics of the reporter antibody. The reporter fluorescence intensity is directly proportional to the amount of analyte (antigen-specific antibody) bound to a given bead set (1, 16). This system thus enables the measurement of antibodies of a given isotype to many antigens in a single reaction well.
|
|
|---|
MAID system for pertussis antibodies. PT and FHA (List Biological Laboratories, Campbell, CA) were covalently linked to carboxylated microspheres (Luminex, Austin, TX) at a concentration of 5 µg per 6,250,000 beads of a given bead set, using a well-described two-step carbodiimide reaction (1, 16). PT was linked to bead sets 108 and 112, and FHA (List) was linked to bead sets 104 and 107. PT 108 and FHA 104 were combined to form duplex 1, and PT 112 and FHA 107 were combined to form duplex 2. A standard serum with assigned values (units/ml) traceable to Center for Biologic Evaluation and Research (CBER) standard lot 3 (PT IgG and FHA IgG) or standard lot 5 (PT IgA and FHA IgA) was serially diluted in phosphate-buffered saline (PBS) containing 1% bovine serum albumin; similarly, evaluation samples were diluted 1:50 in the same buffer. Standard and sample dilutions were added to an equal volume of each duplex (containing 2,500 beads of each bead set) in filter-bottom microtiter wells and incubated for 20 min at room temperature (RT). Following three washes with PBS-0.05% Tween 20 using a vacuum manifold, wells containing duplex 1 received phycoerythrin-labeled goat anti-human IgG (Jackson ImmunoResearch, West Grove, PA) diluted in PBS-0.05% Tween 20, whereas wells containing duplex 2 received phycoerythrin-labeled goat anti-human IgA (Jackson). After another 20-min incubation at RT and three washes, each duplex was resuspended in PBS containing 1% bovine serum albumin; the two duplexes for a given sample were then mixed and analyzed as a tetraplex using a Luminex 100 instrument. For each analyte, median fluorescent intensity (MFI) values were converted to units/ml by interpolation from the relevant standard curve.
In-house (Focus) ELISAs. Separate ELISAs, modified from published procedures (7, 11, 15), were used to measure PT IgG, PT IgA, FHA IgG, and FHA IgA. Microtiter wells were coated with the same antigens used for the MAID system (0.2 µg/well). Diluted secondary standards (traceable to CBER standards) and samples were added to wells and incubated for 2 h at 37°C; after washing, wells received either horseradish peroxidase-labeled goat anti-human IgG or anti-IgA (Jackson) for 1 h at 37°C. After washing, wells received enzyme substrate (tetramethylbenzidine; Moss, Inc., Pasadena, MD) for 10 min at RT and then 1 N sulfuric acid (Ricca, Arlington, TX) to stop the reaction. Absorbance at 450 nM was measured, and sample results were expressed as units/ml based on the standard curves.
Discordance analysis. The following criteria were used to resolve discordant results between the MAID system and the Focus ELISA system. For a given analyte, a finding of concordant normal results for the other three analytes was interpreted as support for the normal result in the discordant pair; similarly, a finding of concordant increased results for the other three analytes was interpreted as support for the increased result in the discordant pair. If these criteria were not met, additional criteria were applied. In the case of PT IgA discordant results, a finding of concordant (normal or increased) results for PT IgG was interpreted as support for the matching qualitative PT IgA result. Likewise, in the case of FHA IgG discordant results, a finding of concordant (normal or increased) results for PT IgG was interpreted as support for the matching qualitative FHA IgG result. In the case of FHA IgA discordant results, a finding of concordant (normal or increased) results for FHA IgG was interpreted as support for the matching qualitative FHA IgA result.
Comparison of MAID values and Focus ELISA values to CVR ELISA values. To determine if MAID and Focus ELISA methods gave values significantly different from the CVR ELISA method, results generated by the three methods for the 20 sera supplied by CVR were log transformed and analyzed using a mixed linear model to account for random effects at the subject level; fixed effects were estimated for the compared method. Statistical models were fitted using the analysis package R (17; http://www.r-project.org). Due to the small sample size, significance was defined as a P value of <0.01.
|
|
|---|
|
View this table: [in a new window] |
TABLE 1. Bound conjugate does not migrate during analysis from one bead set to the comparable bead set bearing antibodies of the same isotypea
|
10% for all analytes, as assessed using one serum sample containing increased levels of all four analytes and another serum sample containing normal levels of all four analytes (data not shown). Between-run coefficients of variation were
16% for the sample with increased antibody levels and
23% for the sample with normal antibody levels (data not shown). A comparison of three separate lots of bead sets demonstrated good reproducibility of the procedure for coupling antigens to beads; in pairwise linear regression analysis of quantitative antibody values for 16 specimens tested using each of the three lots of bead sets, R2 values of >0.95 were obtained for all analytes (data not shown).
![]() View larger version (17K): [in a new window] |
FIG. 1. Standard curves from a representative MAID assay. Units/ml represents the assigned quantitative value for the indicated standard point.
|
Concordance between MAID and in-house ELISA results and resolution of discordant result sets. Pertussis antibodies were measured by both the MAID and Focus ELISA procedures in 220 consecutive sera submitted for pertussis serologic analysis, and the results were defined as normal or increased as described in the previous section. Data for qualitative agreement between MAID and ELISA results are shown in Table 2. Concordance rates for the four analytes ranged from 93% to 99%, with a combined concordance rate of 95%. For the 44 discordant result sets, the other MAID and ELISA pertussis antibody results were examined in an effort to identify support for one of the discordant results. The findings from this analysis are shown in Table 3. Data for the other pertussis antibodies supported the MAID result for 29 discordant result sets (66%) and supported the ELISA result for 10 discordant result sets (23%); the other antibody results did not clearly support either the MAID or ELISA result for 5 result sets (11%).
|
View this table: [in a new window] |
TABLE 2. MAID versus Focus ELISA: qualitative reactivity patterns for 220 consecutive sera submitted for B. pertussis antibody testing
|
|
View this table: [in a new window] |
TABLE 3. Resolution of qualitatively discordant MAID versus Focus ELISA results
|
![]() View larger version (34K): [in a new window] |
FIG. 2. Comparison of PT antibody results obtained by MAID or Focus ELISA to CVR ELISA results. Each line connects the results obtained for a single specimen.
|
![]() View larger version (32K): [in a new window] |
FIG. 3. Comparison of FHA antibody results obtained by MAID or Focus ELISA to CVR ELISA results. Each line connects the results obtained for a single specimen.
|
|
|
|---|
The multiplex microsphere instruments currently available are not configured to allow measurement of different antibody isotypes recognizing multiple immobilized antigens in a single reaction well. Thus, we performed two duplex assays concurrently, one for IgG antibodies and one for IgA antibodies, and then mixed the two duplexes together for analysis. Although each duplex could have been analyzed separately, mixing to form a tetraplex allowed analysis in half the time. Initial experiments indicated that the antigen-coated bead-antibody-conjugate complexes formed prior to duplex mixing were stable and that their fluorescent signals were reliably measured in the tetraplex format.
Our primary requirement for an acceptable MAID assay was that it compare favorably to the Focus ELISA system in its power to discriminate between normal and increased antibody levels. We thus used the 95th percentile value for a group of 100 blood donor sera to define the discrimination point between normal and increased antibody levels for each analyte and then qualitatively assessed concordance between these two methods for a large panel of sera submitted for pertussis serology. The concordance rates were
93% for all four analytes, indicating good qualitative agreement between MAID and Focus ELISA methods. Other pertussis antibody results supported the MAID result for two-thirds of discordant datasets, suggesting that MAID results more often represented the correct results.
The availability of serum standards has enabled the development of pertussis antibody ELISAs that generate comparable results across laboratories (12, 14). We thus sought to demonstrate that the results produced by our new MAID assay were comparable to those generated by another laboratory. Using a small serum panel supplied by CVR, we found that MAID assay results did not significantly differ from those produced by the CVR ELISA system, a well-characterized group of assays that has been used to measure both infection-induced and vaccine-induced antibodies (11). MAID systems for measuring pertussis antibodies should thus prove to be acceptable alternatives to ELISAs.
In our experience, a MAID system offers several advantages over an ELISA system for measuring pertussis antibodies. These advantages include less specimen volume, shorter and fewer incubation periods, and room temperature incubations. Further, the MAID system required lower amounts of antigens per reportable result; the quantity of PT or FHA required to coat 2,500 beads (the bead number used to measure one antibody isotype for one patient specimen) was 100-fold less than the quantity used to coat an ELISA well. Another benefit of a MAID system is the ease with which it can be modified to increase the number of analytes measured, without increasing the required sample volume or assay time. For example, additional bead sets coated with other proteins contained in the current acellular pertussis vaccines (e.g., pertactin, fimbriae) (3) could be added to the current duplexes, allowing measurement of antibodies to all vaccine components in a single analysis well. Thus, laboratories measuring multiple pertussis antibodies in large numbers of samples should see improved efficiency with the institution of MAID assays.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»