Clinical and Diagnostic Laboratory Immunology, July 2005, p. 855-860, Vol. 12, No. 7
1071-412X/05/$08.00+0 doi:10.1128/CDLI.12.7.855-860.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.
HIV Laboratory Branch, Division of HIV/AIDS Prevention, National Center for HIV, STD, and TB Prevention,1 Epidemiology Branch, Division of HIV/AIDS Prevention, National Center for HIV, STD and TB Prevention, Centers for Disease Control and Prevention, Atlanta, GA 30333,3 Cameroon Baptist Convention Health Board, P.O. Box 9, Nso, Northwest Province, Cameroon2
Received 3 May 2004/ Returned for modification 24 June 2004/ Accepted 25 April 2005
|
|
|---|
|
|
|---|
New HIV RT that can use whole-blood specimens have been available for several years; however, little data exist about their performance in rural, resource-poor settings. To address this question, an effective method for assuring the quality of whole-blood RT results is needed. Whole blood dried on filter paper (dried blood spots [DBS]) has been applied in large-scale HIV surveillance studies for well over a decade (13). DBS can easily be collected at the same time as the whole-blood specimens for the rapid HIV assays and could be used to validate the on-site RT results. DBS are well suited for this process, since they are easy to collect, to store, and to ship to larger laboratories for supplemental testing. Several HIV antibody detection enzyme immunoassays (EIA) are approved by the United States Food and Drug Administration (FDA) for use with DBS, and other internationally available assays could be adapted for DBS testing. DBS collection and storage has been well standardized (2), and quality control and quality assurance programs have been in use for over 15 years with effective protocols readily available (14). Our study evaluated the performance of several HIV RT algorithms in rural, prenatal clinics in Northwest Province, Cameroon, and compared the RT results to those determined by EIA and Western blotting (WB) from matched DBS specimens.
|
|
|---|
The laboratory collected 2 ml of whole blood by venipuncture for the prenatal testing, which included HIV, if the patient consented. The blood was dispensed into test tubes containing EDTA and gently mixed to prevent coagulation. Five spots of whole blood (100 µl/spot) were pipetted onto blood collection cards (Schleicher and Schuell grade 903; Keene, NH) from the venipuncture collections. The spots were air dried for 3 to 4 h, put into moisture-resistant bags (Bitran series; Fisher Scientific, Atlanta, GA) with desiccant (Multisorb Technologies, Buffalo, NY), and were stored frozen at 20°C prior to shipment to the Centers for Disease Control and Prevention (CDC), Atlanta, Ga., for testing. The remaining whole blood was centrifuged for 5 min at 1,000 rpm, and the plasma was removed and stored at 4°C. Whole blood was used for the Hema-Strip test; plasma was used for all additional RTs. Trained laboratory staff performed the testing at all sites, and prenatal clinic nurses or counselors provided postcounseling for all of the laboratory results on the same day.
Rapid tests. RTs in the study were Determine HIV-1/2 (DT) (Abbott Laboratories, Tokyo, Japan), Hema-Strip (HS) (ChemBio, Medford, NY), Capillus HIV-1/HIV-2 (CP) (Trinity Biotech, Galway, Ireland), Sero-Card (SC) (Trinity Biotech), and HIV-CHEK (HC) (Johnson and Johnson, New Brunswick, NJ). DT and HS are lateral flow assays; CP is an agglutination assay; and SC and HC are flowthrough, immunodot assays (7). The assays were selected either for their ability to use whole-blood specimens, for their simplicity, or for their capacity to be used as supplied without additional equipment or reagents. The HS tests were performed according to the manufacturer's protocols using whole-blood specimens and were scored accordingly. The remaining tests were performed according to the kit inserts using the plasma aliquots to complete the HIV screen and to resolve discordant results.
Prospective evaluation of rapid testing algorithms. Women (n = 859) attending the three prenatal clinics were tested by two RTs in parallel using whole-blood or plasma specimens. Discordant results were resolved using a third RT. The choice of the third test was dependent on the tests available in the clinics at the time of testing. The data were analyzed as if parallel and serial testing algorithms had been used. Parallel RT algorithms compared the results of two different rapid tests. Concordant reactive and nonreactive specimens were considered definitive, while discordant results were resolved with a third test. The concordant results of two of the three assays were taken as the correct result. The serial testing algorithm considered initially nonreactive specimens as true HIV antibody-negative specimens. Reactive samples were evaluated with a second test and, if reactive, were considered as HIV antibody positive. Discordant specimens were resolved using the third RT results.
HIV-1 serologic testing. The diagnostic assays used to test the DBS, plasma, or whole-blood specimens employ different testing formats and different viral antigens and were used in different combinations to screen and then to confirm initial reactive test results (Table 1). HIV-1 reference testing was performed at the CDC, using DBS protocols approved by the U.S. Food and Drug Administration for the Genetic Systems HIV-1 rLAV (rLAV) kit (Bio-Rad Laboratories, Hercules, CA). Initially reactive specimens were retested by the same assay in duplicate, and samples that were reactive in at least two of the three tests were confirmed by Western blot (WB). WB testing was done using a miniaturized WB method previously described for DBS specimens (12) or by the Novapath HIV-1 Western blot (Bio-Rad Laboratories) as follows. Specimens were prepared by eluting a 6-mm punch of the DBS with 200 µl of 0.15 M phosphate-buffered saline plus 0.05% Tween, pH 7.4 (PBST) (Sigma Chemical Co, St. Louis, MO) for 2 h with shaking, or overnight at 4°C. One-hundred microliters of eluted DBS was added to 900 µl of the specimen diluent in the Bio-Rad WB kit, and the procedure was performed as described in the kit insert. The method was validated and quality controlled using strongly reactive, weakly reactive, and nonreactive DBS controls provided by the National Center for Environmental Health of CDC (15). The HIV-1 EIA/WB testings of DBS were used as the referent results and were performed without knowledge of the RT results.
|
View this table: [in a new window] |
TABLE 1. Characteristics of HIV test products included in the studya
|
![]() View larger version (26K): [in a new window] |
FIG. 3. Comparison of two testing strategies for the determination of HIV antibody status from whole-blood specimens collected on filter paper. N, number.
|
|
|
|---|
HIV rapid testing performance. The study was done to determine the effectiveness of RTs to identify HIV-infected individuals by comparing the RT results with those determined from the matched DBS. However, in field applications many factors can impact the testing process, and, in this case, the selected RTs were not available at all sites throughout the course of the study; thus, the number of tests performed with each assay varied (Table 1). The effectiveness of the RTs was evaluated using serial or parallel testing algorithms. Sensitivity and specificity of each algorithm were calculated based on the total number of RT and matched, definitive DBS results available from the three collection sites (n = 846).
Serial rapid testing algorithm. Field specimens tested by RT were evaluated in a serial testing algorithm (Fig. 1), and the data were compared to the results of the DBS reference testing. DT detected an initial 94 HIV antibody-reactive specimens and 752 antibody-negative reactions (750 true negatives, 2 false negatives). Secondary testing of the initial reactive samples was performed using HS (n = 73) or HC (n = 21). HS found 63 HIV antibody-reactive samples (61 true positives, 2 false positives). Ten specimens had discordant results between DT and HS, and these were retested by either CP or SC. One specimen was reactive by each tertiary test, but both of these were nonreactive by the reference methods (2 false positives). Of the 21 specimens tested by HC, 19 HIV antibody-positive specimens were identified (19 true positives). Two specimens were HIV antibody negative by HC. When these were tested by SC, one HIV antibody-positive and one antibody-negative specimen were identified, and these results were concordant with the DBS results. The sensitivity and specificity of the serial RT algorithm using DT as the screening assay were 97.6% and 99.7%, respectively.
![]() View larger version (23K): [in a new window] |
FIG. 1. Determination of HIV antibody status with rapid tests using a serial testing algorithm. N, number; TN, true negative; FN, false negative; TP, true positive; FP, false positive. TEST 1, Determine; TEST 2, Hema-Strip or HIV-CHEK; TEST 3, Capillus or Sero-Card.
|
![]() View larger version (25K): [in a new window] |
FIG. 2. Determination of HIV antibody status with rapid tests using a parallel testing algorithm. N, number; TN, true negative; FN, false negative; TP, true positive; FP, false positive. TEST 1, Determine; TEST 2, Hema-Strip or HIV-CHEK; TEST 3, Capillus or Sero-Card.
|
Reagent cost of testing algorithms. The reagent cost of testing 846 specimens by the serial testing algorithm was $1,481 ($1.75 per specimen) and was less than half the cost of the parallel algorithm: $2,894 for the 817 specimens ($3.54 per specimen). These costs reflect all testing done within each algorithm, including the resolution of discordant specimens. Both RT algorithms are significantly less expensive than the $7.76 per specimen cost of the EIA/WB for the DBS specimens. The use of two EIAs (UNF and SEL) for the DBS testing reduced the number of WB tests needed to resolve all specimens to 19 (6 HIV-1, 13 HIV-2) and had an average cost per specimen of $2.34.
|
|
|---|
The use of HIV RTs eliminates the indeterminate status that results from the EIA/WB testing algorithm. All of the indeterminate specimens except one were negative by at least two of the RTs and by the UNF and SEL EIAs. Twelve indeterminate specimens had characteristic banding patterns of one to three core antigen-related bands which appear to be nonspecific. In population-based studies, 10 to 15% of the EIA initial reactive specimens may show one or more gag-related bands on WB. However, most of these specimens do not represent developing HIV infections (9, 17). The one specimen that was reactive by the RT and had an indeterminate status could have been a recent infection, since WB results displayed some glycoprotein and polymerase antibody reactivity. Thus, the RT results of these 13 WB-indeterminate specimens that were reported to the patient were consistent with the results of the dual EIA testing strategy for the DBS (except for the one RT-positive specimen) and were probably correct. Efforts were made to determine the outcome of the 13 women with indeterminate HIV WB results, but no additional information was available at this time; thus, these data were excluded from the analyses.
The choice of serial versus parallel rapid testing algorithms relates to cost factors as well as performance. The study by Koblavi-Deme et al. demonstrated that the added cost of the parallel algorithm is about 2.5 times as much as the serial algorithm in reagents alone and was not warranted, since their sensitivity and specificity were not improved (18). A cost analysis of the tests used in this study yielded similar results. In our study, however, two additional HIV antibody-positive specimens would have been identified by the parallel algorithm versus the serial algorithm, albeit with significant increases in reagent costs. The decision on the choice of different RT HIV testing strategies will depend on the performance characteristics of the testing algorithms in a given country or region, the availability of RTs, the purpose of the testing, and the program budgets. For the PMCT program and other VCT in Cameroon, clients with a single negative RT result in the serial RT algorithm are advised about the possible time delay between infection and HIV seropositivity, and they are directed to seek a repeat test in 3 to 6 months. However, blood donations are currently screened using a parallel RT algorithm, which minimizes the risk of HIV infection through contaminated blood products.
Effective methods for providing quality assurance for RT results have not been developed. If DBS specimens were collected at the same time that the RTs were performed, the DBS could be tested later to determine the accuracy of RT results. Tests approved for use with DBS in the United States are not generally available in foreign markets and do not test for antibodies to HIV-2. The third-generation EIAs for the detection of antibodies to HIV now available internationally significantly improved sensitivity by increasing the volume of sample added to the assay. Such volumes are unattainable when eluting DBS, since the amount of serum in a 6-mm punch is approximately 5 µl. However, we did not observe major differences in the ability to detect HIV antibody-positive specimens in our study using the Uniform II plus O assay (only one weakly reactive specimen was not detected). In fact, the signal-to-cutoff ratios (S/CO) were superior to those determined by the rLAV test due to the lower cutoff associated with the UNF assay. Similar observations were noted for the Select HIV-1/2 assay on the limited number of specimens that required additional testing.
The specificities of the UNF and SEL tests were actually superior to that observed with the FDA-licensed rLAV kit, which had a substantial number of repeatedly reactive specimens that were slightly above the cutoff value and had to be resolved by WB. Absorption of moisture by the DBS or exposure to heat are also known to affect DBS quality (15). The initial reactive rate of the DBS specimens tested in this study decreased as personnel became more familiar with DBS collection and storage requirements. With additional modifications, the two EIAs could possibly improve specificity, while yet maintaining the same level of sensitivity. The use of the UNF followed by the SEL test in our study could serve as a model of a dual EIA method for confirming RT results using DBS. Optimal conditions for using existing third-generation EIAs with DBS specimens must be determined and their sensitivity and specificity verified, particularly with recent seroconversion specimens. We are currently evaluating additional EIAs for use with DBS using an elution buffer that would be compatible with the different EIAs and would make a dual EIA testing algorithm for DBS specimens more feasible.
In summary, we have shown the effectiveness of serial and parallel HIV RT algorithms for identifying HIV-infected women in rural clinics in order to institute therapy to reduce perinatal HIV transmission. This program has been greatly expanded in Cameroon, and the efficacy of the intervention strategy is reported elsewhere (24). Additionally, the utility of DBS for confirming HIV RT results and for quality assurance purposes has been demonstrated. Adoption of RT and DBS testing strategies should be considered when expanding HIV testing programs to provide HIV-1 perinatal intervention therapies and to extend seroprevalence studies into global populations.
We acknowledge Marcia Kalish, George Alemnji, and Peter Fonjungo, HIV and Retrovirology Branch, and Mark Rayfield, Division of AIDS, STD, and TB Laboratory Research, National Center for Infectious Diseases, at the Centers for Disease Control and Prevention, Atlanta, Ga., for their technical and laboratory support for this work. Andrea Cedfeldt assisted with this evaluation during a Dartmouth Medical School elective. We thank the laboratory staff at CBCHB facilities for their meticulous HIV testing. Thanks to Steve Soroka and Kim Distel for their assistance with editing of the manuscript. We acknowledge the prenatal patients who had the courage to consent to HIV testing to reduce the risk of HIV infection in their children.