Previous Article | Next Article ![]()
Clinical and Diagnostic Laboratory Immunology, March 2004, p. 272-279, Vol. 11, No. 2
1071-412X/04/$08.00+0 DOI: 10.1128/CDLI.11.2.272-279.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
Health Protection Agency, Vaccine Evaluation Department, Manchester Royal Infirmary,1 Manchester Metropolitan University, Manchester, United Kingdom2
Received 24 July 2003/ Returned for modification 16 September 2003/ Accepted 30 December 2003
|
|
|---|
650 pg/ml. A comparison of the meningococcal bead assay with the standardized meningococcal enzyme-linked immunosorbent assay showed a good correlation between the IgG concentrations obtained by each assay. The tetraplex assay has the potential to be an important addition to the serologic evaluation of meningococcal capsular polysaccharide conjugate vaccines. |
|
|---|
Protection against meningococcal disease correlates with capsular polysaccharide-specific antibody for all serogroups (2) except serogroup B, for which the capsular polysaccharide is poorly immunogenic (21). Evaluation of the immune response to meningococcal vaccination therefore entails serogroup-specific serologic measurements. Assessment of the antibody response to tetravalent conjugate vaccines will involve measurement of an increased number of analytes. The standard methods used in meningococcal serology are the serum bactericidal assay, which measures functional antibody, and the enzyme-linked immunosorbent assay (ELISA), which quantitates meningococcal capsular polysaccharide-specific immunoglobulin G (IgG) (9). The ELISA is a specific, accurate, and reproducible assay that is well suited to the screening of many samples for a single analyte. However, a separate ELISA is required to determine each serogroup-specific antipolysaccharide antibody. Therefore, as the number of target organisms contained in vaccines increases, the ELISA will become increasingly time-consuming and laborious. Furthermore, due to the limited dynamic range of the assay, testing of multiple serum dilutions may be required. Flow cytometry-based multiplex assays incorporating fluorescent microspheres enable the simultaneous determination of multiple analytes in a single sample (23). The technology uses fluorescently distinct microspheres as a solid support for the antigen. This technique, which incorporates all the advantages of the ELISA, will also increase sample throughput and significantly reduce the sample volume required.
In this study, the development of a microsphere-based multiplexed assay for the quantification of serum antibodies against meningococcal serogroups A, C, Y, and W-135, which has the potential to be a useful high-throughput assay and to aid in the evaluation of new multivalent polysaccharide-protein conjugate vaccines, is described. Assay characteristics such as accuracy, sensitivity, specificity, and robustness were determined; and the assay was evaluated by performing a comparison of the multiplex assay and the standardized ELISA.
|
|
|---|
Antisera. A pool of standard human reference serum sample (N. meningitidis) CDC 1992 (NIBSC code 99/706; obtained from 14 adults who had received one dose of meningococcal A, C, Y, and W-135 polysaccharide vaccine [10]) and meningococcal control serum (NIBSC code 96/562; a pool of serum obtained postvaccination with meningococcal A and C polysaccharides) were obtained from NIBSC. Human standard reference serum (lot 89-S; a pool of serum obtained from 17 adults who were immunized with one dose of meningococcal A, C, Y, and W-135 polysaccharide vaccine), one dose of 23-valent pneumococcal polysaccharide vaccine, and a Haemophilus influenzae type b conjugate vaccine [19]) were obtained from the Food and Drug Administration (Frederick, Md.).
Other sera used in this study were obtained from staff at the Manchester Health Protection Agency after routine antibody screening following administration of the meningococcal tetravalent polysaccharide vaccine. Pediatric preimmunization sera (from a meningococcal A and C bivalent polysaccharide vaccine trial) and pediatric pre- and postimmunization sera (from a tetravalent polysaccharide vaccine trial) were also included.
Conjugation of meningococcal polysaccharide antigens to carboxylated microspheres. By using slight modifications of previously published techniques (8, 16), meningococcal polysaccharide was attached to PLL, and this conjugate was covalently attached to microspheres by use of a two-step carbodiimide reaction (22). The meningococcal polysaccharides were reconstituted in pyrogen-free water (Phoenix Pharmaceuticals, Gloucester, United Kingdom) to a concentration of 2 mg/ml. The polysaccharide concentration and incubation times were optimized individually for each serogroup by selecting the conditions that gave the most consistent and appropriate range on the standard curve. Each reconstituted antigen was alkalinized by adding 1.25 ml (2.5 mg of polysaccharide) of serogroup A polysaccharide or 1.75 ml (3.5 mg of polysaccharide) of serogroup C, Y, or W-135 polysaccharide to 1.25 ml of a solution of 0.01% NaOH-0.001% phenolpthalein. The solution was added to cyanuric chloride (5 mg/ml) and vortexed briefly. A solution of 250 µg of PLL/ml was prepared in pyrogen-free water, and 50 µl of this solution (5 µg of polysaccharide per mg) was added to the polysaccharide-cyanuric chloride solution and vortexed briefly. The solution was incubated overnight for approximately 16 h, after which each polysaccharide-PLL-cyanuric chloride solution was purified by use of a Sephadex desalting column (G25 PD-10; Amersham Biosciences, Little Chalfont, United Kingdom) and eluted in 3.5 ml of phosphate-buffered saline (PBS; pH 7.3). The resultant polysaccharide-PLL conjugate was then coupled to activated carboxyl-modified microspheres. In this reaction, 500 µl of beads (12.5 x 106 beads/ml) was added to 500 µl of a solution of PBS (pH 6.1) containing 5 mg of EDC per ml and 5 mg of N-hydroxy-sulfosuccinimide per ml. The solution (which was covered with aluminum foil) was incubated on an orbital shaker (Polymax 1040; Heidolph Instruments, Schwabach, Germany) at 50 rpm for 20 min at room temperature in the dark. The microspheres were washed with PBS (pH 7.3) by centrifugation (12,000 x g for 2 min) and resuspended in 100 µl of the polysaccharide-PLL conjugate. The solution was incubated for 1.5 h (serogroup A) or 2.5 h (serogroups C, Y, and W-135) at room temperature in the dark. The beads were then washed twice with 1 ml of PBS (pH 7.3) containing 0.1% BSA and 0.05% sodium azide at 4°C in the dark and stored in the same mixture.
Microsphere assay for quantification of meningococcal serogroup capsular polysaccharide-specific IgG. Seven fourfold dilutions (1:20 to 1:81,920) of standard reference serum sample CDC 1992 were prepared in PBS containing 5% NBBS. Previously specified concentrations of meningococcal antibodies in CDC 1992 (6, 10) were used in this assay. Control serum samples (89-S and 96/562) and the unknown test sera were diluted 1:100. A total of 25 µl of each dilution of standard and sample (in duplicate) was mixed with one set (monoplex), two sets (biplex), or four sets (tetraplex) of conjugated microspheres. The microspheres were prediluted to a concentration of 5,000 beads/region/well (25 µl). The samples and beads were incubated in a 96-well MV Multiscreen plate filter plate (Fisher Scientific, Loughborough, United Kingdom) for 20 min at room temperature on a plate shaker (WVR International, Poole, United Kingdom) at 500 rpm. The microspheres were collected by filtration with a vacuum manifold (Millipore, Watford, United Kingdom) and washed with PBS. A total of 100 µl of a 1:200 dilution of R-phycoerythrin-conjugated anti-human IgG in PBS was added to each well, and the plate was incubated for 20 min with shaking. Following another wash, the beads were resuspended in 125 µl of PBS and transferred to a Sterilin 96-well U-bottom plate (Fisher Scientific, Loughborough, United Kingdom) before the result was read on a Bio-plex reader (Bio-Rad, Hemel Hempstead, United Kingdom). Data were acquired in real time by use of a computer software package (Bio-plex Manager; Bio-Rad). Data for unknown test sera was generated from a 5-parameter logistic standard curve of the median fluorescent intensity (MFI) against the expected analyte concentration for standard reference serum sample CDC 1992 and converted to micrograms per milliliter.
Specificity assay. A standard control serum sample (NIBSC code 96/562), reference serum specimen CDC 1992, and control serum specimen 89-S were diluted 1:100 in PBS with 5% NBBS. Four aliquots of each serum dilution were prepared, and each aliquot was incubated with 2.5 µg of one of the four purified meningococcal polysaccharides per ml for 1 h at room temperature. Serum diluted in PBS with NBBS only was used as a control. An aliquot (25 µl) of the serum was then mixed with 25 µl of the microspheres (a cocktail of the four bead sets) and assayed as described above.
Assay sensitivity. The MFIs generated from the blank wells were averaged (50 runs), and from this, 2 (positive) standard deviations were calculated for each serogroup. The limit of detection (LOD) was then determined for each serogroup by calculating the concentration (in picograms per milliliter) from the relevant standard curve (for serogroup A, C, Y or W-135). This concentration is equal to the assay LOD for that serogroup.
Assay reproducibility. Intra-assay variation was determined by assaying 15 samples, with each sample assayed on four wells within a plate; thus, four results were obtained for each sample. The coefficient of variation (CV; in percent) between each of these results for each serogroup was calculated and averaged. In order to determine the variation from assay to assay, the samples (n = 15) were run in three separate assays and the percent CV was calculated.
The reproducibilities of the results generated from separate batches of conjugated microspheres were also determined. Three sets of microspheres were conjugated (by using separate preparations of reagents) on the same day for each serogroup. Samples (n = 15) were assayed on the same day by using each preparation of the conjugated beads, and the mean value and the percent CV for each serogroup were calculated.
ELISA for quantification of meningococcal antibodies.
Meningococcal serogroup C-specific ELISAs were performed as described previously for serogroup C (7). A standardized serogroup A-specific ELISA was performed as previously described by Carlone et al. (4), except that reference serum sample CDC 1992 and a different conjugate, monoclonal-PAN anti-human Fc
peroxidase antibody, were used.
Serogroup Y- and W-135-specific ELISAs were performed by a slight modification of the method described above for the serogroup A-specific ELISA. The serogroup Y and W-135 polysaccharides were coated onto microtiter plates (Immulon 2; Thermolabsystems, South Trentham, United Kingdom) with final concentrations of 1 and 2 µg of polysaccharide/ml of methylated human serum albumin, respectively. Reference serum sample CDC 1992 was prediluted 1:75 and, following addition to the plates, was diluted twofold seven times. Following completion of the assay, the optical density was read with an Anthos 2001 plate reader (Labtech, Letchworth, United Kingdom) at 450 nM with a reference filter at 620 nm. Data acquisition was performed with SOFTmaxPRO (version 3.1.2) computer software (Molecular Devices, Sunnyvale, Calif.).
|
|
|---|
![]() View larger version (28K): [in a new window] |
FIG. 1. Comparison of MFIs generated from standard serum run in the monoplex and biplex microsphere assays. (A) Serogroup A; (B) serogroup C; (C) serogroup Y; (D) serogroup W-135.
|
![]() View larger version (22K): [in a new window] |
FIG. 2. Comparison of MFIs generated from standard serum in the monoplex and tetraplex assays. (A) Serogroup A; (B) serogroup C; (C) serogroup Y; (D) serogroup W-135.
|
![]() View larger version (40K): [in a new window] |
FIG. 3. MFIs generated with NIBSC (black bar), CDC 1992 (striped bar), and 89-S (grey bar) sera following incubation with each of the four meningococcal serogroup capsular polysaccharides. (A) Serogroup A beads; (B) serogroup C beads; (C) serogroup Y beads; (D) serogroup W-135 beads.
|
Assay reproducibility.
The reproducibility of the microsphere assay was assessed by obtaining both intra- and interassay variability data and also by observing the variations in the results obtained with different preparations of conjugated microspheres. The mean percent CVs obtained from duplicates of 15 samples within a plate were 4.6% for serogroup A, 4.7% for serogroup C, 5.1% for serogroup Y, and 8.9% for serogroup W-135. Interassay variation was calculated by comparison of the antibody concentrations obtained for samples (n = 15) run in three separate assays. The percent CVs were as follows: 7.8% for serogroup A, 10.9% for serogroup C, 17.5% for serogroup Y, and 13.6% for serogroup W-135. The variation between titers for samples (n = 15) assayed with three different preparations of conjugated microspheres was also investigated (Table 1). For each sample, the mean IgG concentration from the three assays was calculated, and the percent CV between these three results was also determined. For all four serogroups, minimal batch-to-batch differences in the microspheres were observed and the mean percent CV was within the acceptable limit of
25% for all serogroups and for most samples. The exceptions were the percent CVs obtained for serum sample men 4 for serogroups A and W-135, men 5 for serogroup W-135, and men 10 for serogroup C, the CVs for all of which were >25% but <32%.
|
View this table: [in a new window] |
TABLE 1. Mean IgG concentrations and CVs obtained by testing samples with three different preparations of conjugated microspheres
|
![]() View larger version (27K): [in a new window] |
FIG. 4. Comparison of IgG concentrations obtained by the meningococcal ELISA and the microsphere bead assay for serogroup A (A), serogroup C (B), serogroup Y (C), and serogroup W-135 (D).
|
|
View this table: [in a new window] |
TABLE 2. Comparison of IgG concentrations for serogroups C, Y, and W-135 generated from a panel of prevaccination pediatric sera
|
|
|
|---|
The two-step carbodiimide method used for conjugation of polysaccharide to microspheres is both simple and reproducible. Optimization of the conjugation procedure included variation of the incubation times between the polysaccharide-PLL conjugate and the activated microspheres. It was discovered that less time was required to reach optimal conjugation for serogroup A (1.5 h) than for the other serogroups. For serogroups C, Y, and W-135, saturation was not achieved until at least 2.5 h. The meningococcal microsphere assay demonstrated linearity over a seven fourfold standard serum dilution range, which compares to a dynamic range of seven threefold dilutions (serogroup A) and seven twofold dilutions (serogroups C, Y, and W-135) in the ELISA. Such an increase in the dynamic range should reduce the number of sample dilutions required, increase the accuracy of the assay, and permit much lower levels of antibody to be detected.
The possibility of interference and cross-reactivity between bead sets is an important consideration for multiplex assays. Comparison of the MFIs generated by the meningococcal monoplex, biplex, and tetraplex assays demonstrated, however, that no interference between bead sets occurred and multiplexing did not appear to alter the qualities or the sensitivities of the assays.
Competitive inhibition-of-binding studies confirmed that the meningococcal tetraplex assay is specific, and this suggests that the conjugation technique does not have a significant detrimental effect on the important antigenic moieties on the capsular polysaccharide. Addition of homologous polysaccharide (2.5 µg/ml) resulted in a signal reduction, with the levels of inhibition ranging from 60.6 to 95% (for all serogroups). The MFIs generated from serogroup Y- and W-135-specific beads were low for NIBSC serum sample pool 96/562 (Fig. 3) because only naturally acquired antibody is present in this serum pool. Nevertheless, a high level of homologous inhibition was observed for both serogroup Y (94.8%) and serogroup W-135 (75.3%). Addition of up to 80 µg of polysaccharide per ml (data not shown) did not significantly change the percent inhibition obtained. These data suggest that the bead assay is likely to have a higher specificity than the ELISA, in which a minimum of 200 µg of homologous polysaccharide per ml is required to inhibit specific antibody binding (data not shown). The level of heterologous inhibition in the bead assay was low and varied between 0 and 20.6%. Due to similarities in the bacterial capsular polysaccharide structures, a low level of cross-reactivity between the four serogroups is not unexpected. The specificity arises from the differences in the monosaccharides: the serogroup A polysaccharide is composed of an
1
6-linked N-acetyl-D-mannosamine-1-phosphate repeating unit, whereas the serogroup C polysaccharide contains
2
9-linked N-acetyl neuramic acid (sialic acid) (18). Serogroup W-135 and Y polysaccharides also contain sialic acid and differ from one another only by the presence of a galactose (serogroup W-135) or a glucose (serogroup Y) (11).
The LOD is the lowest level of antibody response that can be accurately distinguished from a true-negative result, and this can be determined statistically by using values obtained from the blanks. The LOD concentrations calculated for the tetraplex assay ranged from 370 to 650 pg/ml. This implies that the bead assay has a sensitivity much greater than that of the standardized ELISA, with the LODs of the bead assay being approximately 100-fold lower than those of the ELISA.
The variability of the assay on a run-to-run basis was minimal (CV < 18% for all serogroups). The results for replicates of standards from several separate runs also exhibited minimal variation (data not shown), suggesting that the tetraplex assay exhibits good precision. Intra-assay variation was also shown to be very low (CV < 9% for all serogroups). Furthermore, the variation in the data obtained by using separate preparations of conjugated beads was low, suggesting that the two-step carbodiimide methodology, which incorporates PLL, is highly reproducible. Although some of the CVs exceeded the cutoff limit of 25% (Table 1), these samples contained very high or very low levels of antibody; and the readings generated from these areas of the standard curve are likely to be somewhat more variable, especially between separate preparations of beads. The fluorescent readout from the Bio-plex reader was also shown to be consistent across the 96-well plate (data not shown) and is likely to be more stable than the colorimetric readout of the ELISA, which relies on enzyme amplification.
The IgG concentrations obtained with sera tested by the microsphere assay demonstrated a good correlation with those obtained by the standardized ELISA. The results of the microsphere assay for adult sera and also pediatric pre- and postvaccination sera correlated well with those of the ELISA for serogroups A, C, and W-135. For serogroup Y the overall correlation of the results obtained by the tetraplex assay and the ELISA was reasonable. However, a number of pediatric prevaccination sera from a particular study gave a result of half the LLQ by the ELISA yet generated IgG levels in the range of 0.01 to 0.9 µg/ml in the tetraplex assay. This observation appears to be serum sample specific, because analysis of pediatric prevaccination sera from a different study demonstrated that for serogroup Y, the tetraplex assay is more sensitive than the ELISA and gave acceptable results for these samples compared to the results obtained by ELISA, which were less than the LLQ. The reason for this discrepancy between the two assays is unclear; however, it is likely that the tetraplex assay detects serogroup Y polysaccharide-specific IgG at an extremely low level that is undetectable by the ELISA. It should be noted that these IgG levels are below the putative protection level of 2 µg/ml against serogroup A determined in Finnish efficacy trials (12, 14).
Use of the multiplexing technique in place of the ELISA for quantification of meningococcal antibodies in serum would significantly reduce the amounts of time and labor expended. For example, by using the present standardized ELISA, 20 samples can be tested for all four serogroups in 1.5 days, whereas the microsphere assay would require approximately 3 h. Minimal user training is required to use the Bio-plex instrument, as the software is simple and data acquisition is performed in real time; hence, the rapidity of the assay is enhanced even further.
An advantage of microsphere assays is their flexibility for expansion to include new targets of interest. As 100 bead sets are available, in theory, a single sample could be analyzed for 100 analytes. The assay could be expanded to include detection of antibodies to Streptococcus pneumoniae (16) and H. influenzae and could be fully validated in a manner to similar that for the ELISA. For example, a recent study developed a multiplex flow cytometric assay for quantitation of antibodies to the pathogens that cause tetanus and diphtheria and antibodies to H. influenzae (17).
In conclusion, the multiplex assay developed in the present study is sensitive and rapid and shows good specificity, and the results of the assay demonstrate a good correlation with those of the ELISA for quantitation of the serum IgG antibody response to meningococcal capsular polysaccharides. The microsphere assay has the potential, therefore, to become a viable alternative to the standard ELISA, especially since the number of analytes is set to increase with the development of tetravalent meningococcal conjugate vaccines.
We thank Helen Swift for performance of the meningococcal ELISA.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»