This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Knight, C. S.
Right arrow Articles by Hardy, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Knight, C. S.
Right arrow Articles by Hardy, R. W.

 Previous Article  |  Next Article 

Clinical and Vaccine Immunology, June 2007, p. 710-713, Vol. 14, No. 6
1071-412X/07/$08.00+0     doi:10.1128/CVI.00068-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.

Evaluation of the LIAISON Chemiluminescence Immunoassay for Diagnosis of Syphilis{triangledown}

Carrie S. Knight, Mary A. Crum, and Robert W. Hardy*

Department of Pathology, Division of Laboratory Medicine, University of Alabama at Birmingham, Birmingham, Alabama 35233

Received 30 January 2007/ Returned for modification 21 March 2007/ Accepted 11 April 2007

We report the results of an evaluation of the LIAISON Treponema pallidum-specific assay, a one-step sandwich chemiluminescence immunoassay (CLIA), as a screening test and as a confirmatory test for the diagnosis of syphilis. The assay was compared with the CAPTIA Syphilis-G enzyme immunoassay (EIA) and with a testing algorithm that also included the rapid plasma reagin (RPR) and T. pallidum particle agglutination (PA) assays. As a screening test, the CLIA showed levels of agreement with the EIA and with the algorithm, respectively, of 94.1 and 100% for 51 samples from patients with primary or secondary syphilis, 93.2 and 98.7% for 999 samples sent to the laboratory for routine syphilis testing, 84.5 and 94.0% for 200 samples from human immunodeficiency virus-positive patients, 98.0 and 100% for 200 samples from pregnant patients, and 94.3 and 98.3% for 992 samples from apparently healthy adults. As a confirmatory test, the CLIA showed 99% agreement with the EIA for 204 RPR-positive samples. After resolution with further T. pallidum PA testing and the discarding of one sample of insufficient quantity, there was 100% agreement for the remaining 203 samples. For the total group of 2,645 samples, the overall relative sensitivity was 95.8% and the relative specificity was 99.1%. We conclude that the LIAISON CLIA demonstrated excellent sensitivity and specificity when evaluated as a confirmatory test and as a screening test for syphilis among various patient populations, including specific populations with reportedly increased rates of false-positive nontreponemal test results.


* Corresponding author. Mailing address: Department of Pathology, P230 West Pavilion, University of Alabama at Birmingham, 619 South 19th St., Birmingham, AL 35233. Phone: (205) 934-9925. Fax: (205) 975-9927. E-mail: hardy{at}path.uab.edu

{triangledown} Published ahead of print on 25 April 2007.


Clinical and Vaccine Immunology, June 2007, p. 710-713, Vol. 14, No. 6
1071-412X/07/$08.00+0     doi:10.1128/CVI.00068-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Kingston, M, French, P, Goh, B, Goold, P, Higgins, S, Sukthankar, A, Stott, C, Turner, A, Tyler, C, Young, H (2008). UK National Guidelines on the Management of Syphilis 2008. Int J STD AIDS 19: 729-740 [Full Text]