The suitability of frozen serum after storage in primary sampling tubes with a gel separator for serological enzyme-linked immunosorbent assay testing (hepatitis B virus surface antigen [HBs Ag], anti-HBs Ag, anti-Toxoplasma gondii immunoglobulin G [IgG], anti-rubella virus IgG, anti-cytomegalovirus IgM, and anti-Epstein-Barr virus IgM) was evaluated for 375 samples. No difference was found among test results using fresh or stored frozen serum